The part library
Every part lives in your library: organise it in projects and folders, use it in other designs as a linked component, and let changes flow to everything that uses it.
What the part library is
The part library holds every part you make or bring in, in projects and folders. A part is either a Design Project (solids and assemblies, made in Design) or a Surface Project (meshes and surfaces, made in WindFire Surfaces). The library is the same in Design, CAM and WindFire Surfaces.
Use it to find your parts, to use one part in other designs (as a linked component that follows the original), to see where a part is used before you change or delete it, and to start CAM from a part.

Projects, folders and parts
Projects are the top level (for example one per customer or product). Folders inside a project can hold folders of their own. Every saved design is a Design Project in the library: the first save puts it into your first project (My Projects when there is none yet), and you can move it later.
- Click New Project, type a name, press OK.
- Choose the project, then click New Folder to add a folder in it (or in the folder you chose).
- Drag parts and folders onto a project or folder on the left to move them, or right-click > Move….
Search parts looks through every project; each result shows the project and folder it is in.
Open a part
Double-click a part, or select it and click Open. A Design Project opens in Design. A Surface Project cannot be edited in Design: it comes into the current design as a linked copy instead, and right-click > Open on it edits the original in WindFire Surfaces.
Mixed STEP: solids and native surfaces
This workflow imports a supported STEP part with multiple solid bodies and open native surface bodies into one Design. Every admitted source body must be matched and displayable; a failure refuses the upload rather than silently dropping bodies. It is not a general assembly importer.
Sign in, open Part Library, choose a project/folder and select Upload. Choose a STEP file of at most 48 MiB. Wait for the body summary and confirmed account save before opening the new part. The Design document also has a 24 MiB account limit.
Check the counts and names. The example has five bodies: three solids and two native surfaces. A nonempty geometric-item name takes precedence over its product name. Product names remain source metadata; absent body names receive an explicit fallback. Native surfaces are labeled Surface in the body tree.
Double-click the saved library part to open it. A fresh browser context can reopen it from the account source and document. Save success requires server readback of the source, Design, library version and embedded artifacts; a local cache alone does not confirm success.
Dropping STEP into the open Design uses a preview. Confirm to commit it, or Cancel to restore the prior document. Ordinary Undo/Redo removes/restores the complete committed import. The library Upload action creates a separate library Design.
Source units are required. Declared STEP lengths are converted to millimeters once by the native reader. Changing the project display to inches does not reinterpret or rescale the source. The example deliberately uses an inch display for a millimeter source.
In the native-retention path: Native surfaces are not filled, thickened or converted to faceted meshes by this workflow. Surface Trim and Thicken remain separate modeling operations. Solid Join/Cut/Intersect require solid tools and solid targets; selecting a native surface refuses that solid operation without deleting the surface.
Native pole tessellations may contain exactly zero-area display triangles. Only those display primitives are removed, with face ownership and counts recorded. Native CAD bodies and source bytes are unchanged. Empty bodies, disappearing meshed faces, malformed indices or missing normals refuse admission.
Unsupported assembly occurrences, ambiguous correspondence, multiple parts in one source body, unsupported units and invalid geometry still refuse the file. Source appearance fidelity and general assembly hierarchy remain unqualified. The qualified facet choice is described below.
If sign-in, entitlement, storage, network or readback checks fail, the upload remains an error. An account, destination or Design change cancels the pending action. Reopen the library in the intended account and retry; do not treat a local preview as an account save. Server artifacts already confirmed before a later failure are retained for recovery.


Typed faceted STEP: mesh or native geometry
Use Part Library → Upload, or drop STEP into Design. After the complete file is checked, source-explicit supported facets offer Import as meshes, Keep native geometry and Cancel. The mesh choice is the default. Solids remain solids and open surfaces remain surfaces when native geometry is kept. This replaces the earlier provisional “Keep as Surfaces” wording; it does not change source topology.
Only complete supported FACETED_BREP bodies or explicit planar triangle/quad POLY_LOOP shell bodies qualify for mesh conversion. Ordinary native CAD solids stay native even when all faces are planar. Curved, holed or otherwise unqualified bodies remain native as whole bodies. Names and source identity are preserved for admitted bodies. Supported placed occurrences and skipped-content reporting are described below.
Confirm the body counts before opening the saved part. Mesh labels distinguish the two raw facet bodies in this synthetic example from its three native solids. Upload success requires the existing account source, Design, library-version and artifact readbacks. Reopening in an empty browser cache regenerates the chosen representation from the exact original STEP. Source units become millimeters once; an inch display does not rescale the source.
Meshes have triangle geometry, not editable native CAD faces. Supported actions include direct body placement/Copy and bounded uniform scale or non-joined body mirrors, mesh area and point-to-mesh distance, and separate printing files. STEP export, native booleans, native drawings/projections, sheet development, general joint/captured component replay (except the static imported occurrences described below) and versioned mesh patterns refuse mesh operands. Volume, mass and center of mass are not qualified, including for a closed-looking mesh. A display material is not a physical mass claim.
Machine it keeps the selected part first and the other visible bodies as fixtures. A mixed selection containing a mesh uses a named millimeter OBJ container, with every selected body triangulated. Pure-native handoff keeps STEP. The existing Mesh Auto path supports its own accessible-mesh checks, flat/ball tools, stock/depth and height refusals. It is not a new guarantee of fixture clearance, continuous cutting safety or physical machining readiness. Temporary OBJ naming limit: leading/trailing whitespace, repeated spaces, tabs or line breaks that cannot round-trip exactly are refused. Rename the affected bodies before Machine it; the Design and original source names are not silently rewritten.
An original-source library Upload can be opened and restored as a Design. Later edited mesh Designs must be saved/opened with their original sources; a general STEP library snapshot is unavailable and is explicitly held. Do not treat an offline draft or preview as a confirmed account save. Missing or changed source/representation, failed steps and stale callbacks refuse output rather than silently exporting an earlier transform.
Resource budgets limit the complete mesh file, raw geometry, copies and handoff. Reduce the file or split the Design when a named limit is reached. No body is partially converted, filled, healed or silently discarded. Mesh conversion is an import representation choice, not general assembly, arbitrary mesh CAD, 3DM, solidness, material or physical qualification.


Placed STEP assemblies and skipped content
Use Part Library → Upload, or drop a STEP file into Design. Supported rigid, source-mapped occurrences keep their product/body names, hierarchy and repeated placements. In this example five source bodies form two placed occurrences: six solids and four meshes, not ten independent source bodies. Imported occurrences do not create mechanical joints or motion constraints.
The existing mesh/native choice also shows any skipped content. Library upload success and the Insert feature’s STEP import notes name the source items and list standalone face, edge or vertex counts. Counts are diagnostics: the same omitted geometry may appear in more than one row. For example, a named reference curve set can also contribute one edge and two vertices. These curves are not imported as sketches.
Readable admitted bodies can be retained while unsupported standalone content or unresolved occurrence branches are reported. Ambiguous body ownership, invalid native geometry, missing length units and resource-limit failures still hold the file. This is bounded rigid-occurrence support, not a general assembly, healing or repair service. STEP display colours/materials and assembly joint semantics are not restored by this workflow.
Import as meshes converts only the already supported complete source-explicit facet bodies. Keep native geometry preserves native solids and open surfaces. Original units become millimeters once, independently of the Design display unit; Insert placement and scale then apply once to the whole imported hierarchy.
Cancel the representation choice before upload, or Cancel a pending Insert to restore the previous bodies, components and history. A confirmed Library Upload retains the original STEP and Design document through the existing account save/readback checks. Reopen the saved Design to regenerate its selected representation and hierarchy. Mesh-containing Designs cannot be republished as a STEP snapshot; retain the source-backed Design.


Upload a part
Upload turns a file from your computer into a part:
| You upload | It becomes |
|---|---|
| STL, OBJ, 3MF, PLY (mesh / surface) | a Surface Project (the mesh is kept as one STL; 3MF units are converted to mm) |
| STEP | a Design Project, made through Design: a design whose first step is the part |
- Choose the project or folder.
- Click Upload… and pick the files, or drop them on the dashed area.
- The new part is selected and the line at the bottom says what it became.
Other file types are refused with the reason. WindFire Surfaces accepts only mesh and surface data.
Insert into current design
With a design open, select another part and click Insert into current design (or ASSEMBLE > Insert from Library…). It comes in as a linked component (⛓) inside the active component: the geometry is read-only here, but you can position it, joint it, pin it, ground it to its parent and hide it like any component.
A part cannot be inserted into itself, not even through another part (a design that uses this design): such parts are dimmed and the button stays off.
Versions and Get latest
Every explicit Save (the Save button, Ctrl+S) of a design adds a version to its Design Project, with an embedded STEP copy that other designs use. Uploading a Surface Project makes its first version. The details show every version with its date; the newest is marked latest.
Designs that use a part always follow its latest version (see Automatic updates). ASSEMBLE > Update All Linked Parts gets the latest versions by hand, for example after working offline.
Uses and Used In
Select a part to see what it uses (the parts linked into it) and where it is used in (designs that link it, and CAM files that machine it). Check Used In before you change a part a lot or delete it.
Rename, Move, Delete
Right-click a part, folder or project for Rename, Move… and Delete.
- Delete a part that is used: a warning lists every design and CAM file that uses it. If you delete anyway, they keep their embedded copy, marked "original unavailable" (⊗).
- Delete a folder or project with parts in it: you are asked whether to delete the parts too.
- A folder cannot be moved into itself.
Select and open
The library shows parts as cards with a preview picture of the part, or as a list (the ☰ / ▦ button). The picture is made when the part is saved, from the bodies in an iso view; parts saved before have a drawing of their kind until their next save.
| Do | To |
|---|---|
| Click (tap) | select a part: it is highlighted, its ▸ version toggle appears and the buttons below work on it |
| Double-click (double-tap) or Enter | open it in its own module; in a picker (Insert, CAM New) it picks it, like a click and then Choose |
| Ctrl+click, Shift+click | select several parts, for Archive and Delete |
| Right-click, Shift+F10 or the menu key | the menu of the selected part |
| F2 / Del | Rename / Delete |
The Designs list on the left of Design works the same way: one click selects a design, a double-click or Enter opens it.
Version history and Restore
Every save adds a version. Select a part and click ▸ (or right-click > Version History): its versions open underneath, the newest first, each with its number, date, comment or milestone and its preview.
- Click an earlier version.
- Confirm: the version you have now is kept first as a new version ("Before restoring vN"), then the one you clicked is saved as the newest. Nothing is lost.
- Designs that use the part update to it the same way as after any save.
⋯ next to a version offers Open vN (read only) (look at it without changing anything) and Delete version (never the latest version or a milestone).
If the part is the design open in Design, Design saves your open work first and then brings the version back into the editor; Undo also goes back.
Archive, Delete and the Trash
- Archive hides a part from the folders and pickers without deleting it. Designs that use it keep working. Find it under Archived; Unarchive puts it back.
- Delete moves a part to the Trash; Undo on the status line brings it back at once, Restore later. A part that is still used somewhere cannot be deleted: the library lists where it is used; remove it there or archive it.
- Delete permanently is only in the Trash, and cannot be undone.
Rename works in place (type the new name, Enter keeps it, Esc cancels); linked components keep their link.
Automatic updates
When the original gets a new version, every open design that uses it updates its linked component at once, also in other browser tabs, and the status line says what changed; Undo goes back. A design opened later updates when it opens.
If an update cannot run (offline, the embedded copy not on this device yet, a failed rebuild), ⚠ marks the linked component and every component above it. ASSEMBLE > Update All Linked Parts runs it when it can.
To keep a fixed copy that never updates, right-click the linked component > Break Link.
What each module may do
- Design opens Design Projects and inserts both kinds.
- WindFire Surfaces opens and imports only Surface Projects and mesh / surface data; a Design Project is opened in Design.
- CAM machines parts from the library: New picks a Design Project or a Surface Project. A STEP goes into the library as a Design Project first.
Choosing a part for CAM
CAM New opens the library as a picker: only the kinds that CAM can machine are listed. Select the part and click Choose. The CAM file then shows in the part's Used In list.
On this device and in your account
The library is kept on this device and, when you are signed in, in your account, so it is the same on your other devices. Embedded copies are uploaded with each version. Offline you keep working with what is on this device; the account catches up later.
Worked example: one bracket in two fixtures
- Open the bracket design and click Save: it is a Design Project, version 1.
- Open the first fixture design, click Part library, select the bracket and click Insert into current design. Do the same in the second fixture.
- Back in the bracket, make the slot longer and Save: version 2.
- Both fixtures update to version 2 at once (or when they are opened). The bracket's Used In lists both fixtures.
Messages and how to fix them
| Message | What to do |
|---|---|
| A part cannot be inserted into itself, not even through another part. | The part uses the design you are in. Insert something else, or Break Link in the part first. |
| That version has no embedded copy yet. Save it again in its own module. | Open the original and Save it (a design with no bodies has nothing to embed). |
| The embedded copy is not on this device. Sign in to get it from your account. | Sign in; the copy comes from your account. |
| WindFire Surfaces opens only Surface Projects. Open this Design Project in Design. | Open it in Design. |
| Use STL, OBJ, 3MF or PLY for a Surface Project, or STEP for a Design Project. | Export the part in one of these formats first. |
Tips
- Save the original after a change you want to share: the designs that use it follow at once.
- Check Used In before deleting or reworking a part.
- Use folders for bought parts, fixtures and customer jobs.
- Break Link when a design must keep an old shape.